The Komet Range of Ammonia and Nitrate Analysers with In-Tank Filtration for Wastewater Treatment
The Komet range was developed in response to shortcomings that Photonic Measurements identified through its long-standing work with customers worldwide. A common problem was that analysers could not take a sample directly from biological treatment tanks. Without reliable in-tank real-time data, plant operators had no choice but to run blowers harder than needed just to stay within discharge consent and ensure compliance. That meant higher energy bills, increased operating costs and a bigger carbon footprint. Following consistent customer feedback, Photonic Measurements introduced the Komet range to address these issues.
The challenge is not unique to Photonic Measurements’ customers. Research for the Sustainable Energy Authority of Ireland has found that aeration can account for 45–75% of total plant energy use. At the same time, tightening regulation, including the EU’s revised Urban Wastewater Treatment Directive requires larger plants to remove nitrogen and phosphorus by 2039 and to be energy neutral by 2045, is making accurate, real-time process monitoring essential for nutrient removal worldwide.
“Time and again, our customers told us the same thing: they had invested in an analyser, only to find it couldn’t take a sample from the treatment tank,” said John McKenna, Sales Director at Photonic Measurements. “We set out to solve that problem at its source. With unique filtration and automated-cleanse built into the Komet analysers, we’re making it simple for plants to get reliable, real-time data.”
Ammonia Analyser With Integrated Filtration
The Komet ammonia analyser is supplied with its own ceramic membrane filtration unit, which sits directly in the activated sludge (biological treatment) tank of a wastewater treatment plant (WWTP) and delivers a filtered sample to the analyser which is also fitted with an automated cleaning system. No additional filtration equipment is needed, and the system provides stable, accurate ammonia-nitrogen monitoring data.
Nitrate Analyser For Real-Time Denitrification Control
The Komet nitrate analyser is also supplied with in-tank ceramic membrane filtration and an automatic cleaning system, so it too can draw its sample directly from the aeration tank. It delivers real-time online nitrate monitoring for nitrogen removal, giving plants reliable data to optimise their denitrification processes, improve operational efficiency and raise effluent water quality.
Cutting Energy Costs By ~ 25% Whilst Reducing Carbon And Compliance Risk
With aeration accounting for up to 75% of the energy used at a wastewater treatment plant, how it is controlled has a significant impact on energy costs, compliance and the environment. Real-time ammonia, nitrate and dissolved oxygen data enables precise aeration control, so operators supply only the air the process needs, cutting blower energy use and avoiding wasteful over-aeration. More precise control of denitrification also reduces unnecessary chemical and carbon source dosing.
The result is lower operating costs, a smaller carbon footprint and more consistent effluent quality, helping plants comply with their discharge consents and protect the rivers and coastal waters they discharge into.
A Complete Multi-Parameter Range
Alongside the ammonia and nitrate analysers, the Komet range covers the parameters most commonly monitored at wastewater treatment plants:
- Residual chlorine
- pH and ORP
- Dissolved oxygen
- Turbidity
- Suspended solids (sludge concentration)
- Liquid level
Together, these meet the need for online multi-parameter monitoring throughout the wastewater treatment process.
Photonic Measurements remains committed to providing high-quality water analysis instruments and professional service to customers globally.